Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Rev. odontol. UNESP (Online) ; 43(4): 236-240, July-Aug/2014. tab, ilus
Article in English | LILACS, BBO | ID: lil-714863

ABSTRACT

Introduction: For presenting wide antibacterial activity, chlorhexidine (CHX) has been extensively used in dentistry and can be easily incorporated into the glass ionomer cement (GIC) and consequently released into the oral cavity. Aim: The aim of this study was porosity and compression strength of a GIC, that was added to different concentrations of CHX. Material and Method: Specimens were prepared with GIC (Ketac Molar Esaymix) and divided into 4 groups according to the concentration of CHX: control, 0.5% and 1% and 2% (n = 10). For analysis of pores specimens were fractured with the aid of hammer and chisel surgical, so that the fracture was performed in the center of the specimens, dividing it in half and images were obtained from a scanning electron microscope (SEM) analyzed in Image J software. The compressive strength test was conducted in a mechanical testing machine (EMIC - Equipment and Testing Systems Ltd., Joseph of the Pines, PR, Brazil). Statistical analysis was performed by ANOVA, Tukey test. Significance level of 5%. Result: No statistically significant changes between the study groups was observed both for the number of pores as well as for the compressive strength. Conclusion: The use of GIC associated with CHX gluconate 1% and 2% is the best option to be used in dental practice. .


Introdução: Por apresentar ampla atividade antibacteriana, a clorexidina (CHX) tem sido amplamente utilizada em odontologia, podendo ser facilmente incorporada ao cimento de ionômero de vidro (CIV) e liberada consequentemente na cavidade bucal. Objetivo: O objetivo neste estudo foi avaliar a porosidade e resistência à compressão de um CIV, ao qual foi adicionado diferentes concentrações de CHX. Material e Método: Os espécimes foram preparados com CIV (Ketac Molar Esaymix) e divididos em 4 grupos de acordo com a concentração de CHX: controle, 0,5% e 1% e 2% (n=10). Para análise dos poros os espécimes foram fraturados com auxílio de martelo e cinzel cirúrgicos, de modo que a fratura era realizada no centro do corpo de prova, dividindo-o ao meio e as imagens obtidas no microscópio eletrônico de varredura (MEV) analisadas no software Image J. O teste de resistência à compressão foi realizado na máquina de ensaios mecânicos (EMIC - Equipamentos e Sistemas de Ensaios Ltda, São José dos Pinhais, PR, Brazil). A análise estatística foi realizada por ANOVA, complementada pelo teste de Tukey. Nível de significância adotado de 5%. Resultado: Não se observou alteração estatisticamente significante entre os grupos estudados tanto para o número de poros quanto para a resistência à compressão. Conclusão: O uso de CIV associado ao gluconato de CLX a 1% e 2% é a melhor opção para ser utilizada na clínica odontológica. .


Subject(s)
Microscopy, Electron, Scanning , Chlorhexidine , Analysis of Variance , Porosity , Glass Ionomer Cements
2.
Braz. j. oral sci ; 13(1): 70-75, Jan-Mar/2014. tab
Article in English | LILACS | ID: lil-709506

ABSTRACT

AIM: To evaluate the clinical and radiographic success of endodontic treatment in human primary teeth with necrotic pulp with and without radiographically visible furcal/periapical lesion treated with a calcium hydroxide (CH) and chlorhexidine (CHX) intracanal dressing. The tested hypothesis was that there is no difference in the clinical and radiographic success in primary teeth medicated with CH pastes prepared with polyethylene glycol (PEG) or CHX. METHODS: Thirty-two teeth with necrotic pulp were used in this randomized clinical study: 12 without and 20 with lesion. Canals were prepared and medicated with CH pastes with polyethylene glycol (CH/PEG) (n=16) or 2% CHX gel (CH/CHX) (n=16). Definitive filling was done after 30 days. The teeth were clinically and radiographically examined during 12 months to determine the success of the endodontic therapy. Data from clinical and radiographic examination of the initial condition and 12 months after treatment were compared using the Z test (α = 0.05). RESULTS: There was no significant difference (p>0.05) in the success rate of teeth with and without lesion medicated with CH/PEG or CH/CHX. No significant difference (p>0.05) was found between the pastes regardless of the presence of lesion. CONCLUSIONS: Combination of CHX and CH was not more effective than the CH/PEG paste, as similar clinical and radiographic success rate was observed in teeth medicated with either type of intracanal dressing.


Subject(s)
Humans , Anti-Infective Agents, Local/therapeutic use , Chlorhexidine/therapeutic use , Dental Pulp Necrosis , Calcium Hydroxide/therapeutic use , Tooth, Deciduous
3.
Braz. dent. j ; 25(1): 33-37, Jan-Feb/2014. tab, graf
Article in English | LILACS | ID: lil-709399

ABSTRACT

The objective of this work was to determine the effect of different concentrations of chlorhexidine digluconate (CHX) on setting time, surface hardness, maximum tensile bond strength and antibacterial activity of a glass ionomer cement (GIC). The material used as control was Ketac Molar Easymix GIC. CHX was incorporated into the GIC during its manipulation at concentrations of 0.5, 1.0 and 2.0%. Antimicrobial activity against S. mutans and L. acidophilus was evaluated by means of agar diffusion test. Tensile bond strength data were analyzed statistically using Analysis of variance and Tukey's test. Setting time, Vickers hardness and agar diffusion test were analyzed using Kruskal-Wallis and Mann-Whitney tests at a significance level of 5%. It was observed that adding CHX at concentrations of 1% and 2% increased significantly the setting time of the material (p=0.012 and p=0.003, respectively). There was no significant difference between control and 0.5% CHX groups regarding the setting time. Addition of 2% CHX decreased significantly the surface hardness in relation to the control group (p=0.009), followed by the 1% CHX group (p=0.009). The tensile bond strength of the material also decreased significantly after adding CHX at a concentration of 2% (p=0.001). Addition of CHX promoted formation of an inhibition halo in both bacterial strains for all concentrations. The results showed that the best option for clinical use of GIC with CHX is at 0.5% concentration, since antibacterial activity increased and the physical-mechanical properties remained unchanged.


O objetivo deste trabalho foi determinar o efeito de diferentes concentrações de gluconato de clorexidina (CLX) sobre o tempo de presa, dureza superficial, resistência máxima a tração e atividade antibacteriana de um cimento de ionômero de vidro (CIV). O material utilizado como controle foi o CIV Ketac Molar Easymix. O gluconato de CHX foi incorporado no CIV durante a sua manipulação, em concentrações de 0,5, 1,0 e 2,0%. Atividade antimicrobiana contra S. mutans e L. acidophilus foi avaliada por meio de teste de difusão em ágar. Análise de variância (ANOVA) e teste de Tukey foram usadas para avaliar a resistência a tração do material. Para avaliar tempo de presa, dureza Vickers e teste de difusão em ágar foram usados os testes de Mann-Whitney e Kruskal-Wallis ao nível de significância de 5%. Observou-se que a adição de CHX, em concentrações de 1% e 2%, aumentou significativamente o tempo de presa do material (p = 0,012 e p = 0,003, respectivamente). Não houve diferença significativa entre os grupos controle e CHX 0,5% em relação ao tempo de presa. A adição de 2% de CHX diminuiu significativamente a dureza superficial, em relação ao grupo controle (p = 0,009), seguido pelo grupo 1% de CHX (p = 0,009). A resistência à tração do material também diminuiu significativamente após a adição de CHX a uma concentração de 2% (p = 0,001). A adição de CHX promoveu formação de halo de inibição em ambas as linhagens bacterianas para todas as concentrações. Os resultados mostraram que a melhor opção para o uso clínico de CIV com CHX está numa concentração de 0,5%, uma vez que a atividade antibacteriana aumentada e as propriedades físico-mecânicas permaneceram inalteradas.


Subject(s)
Anti-Bacterial Agents/chemistry , Chlorhexidine/analogs & derivatives , Glass Ionomer Cements , Anti-Bacterial Agents/pharmacology , Chlorhexidine/chemistry , Lactobacillus acidophilus/drug effects , Materials Testing , Microbial Sensitivity Tests , Streptococcus mutans/drug effects
4.
Rev. odontol. UNESP (Online) ; 42(3): 172-175, maio-jun. 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-678419

ABSTRACT

Introdução: O cimento de ionômero de vidro é um material odontológico que apresenta limitações de uso devido às suas propriedades mecânicas, como baixa resistência ao desgaste, microdureza, compressão e tração diametral. Com base nisso, este estudo investigou o efeito da excitação ultrassônica sobre o CIV, em diferentes tempos de aplicação, por meio da resistência à tração diametral. Material e Método: Os materiais utilizados foram o Ketac Molar Easymix (KME) e o Ketac Cem Easymix (KCE). Foram confeccionados 10 corpos de prova para cada condição estudada: grupo controle, e os grupos que receberam aplicação de ultrassom por 15s, 30s e 45s, para ambos materiais. A excitação ultrassônica foi aplicada durante a reação de presa inicial do CIV, logo após sua inserção na matriz de silicone. Os valores de resistência à tração diametral foram analisados pelo teste Shapiro Wilk e Anova (α = 0.05). Resultado: A aplicação de excitação ultrassônica não apresentou efeito estatisticamente significante na resistência à tração diametral dos materiais testados, independente do tempo de aplicação (p > 0,05). O KME apresentou resistência estatisticamente maior que o KCE (p = 0,023). Conclusão: A utilização das ondas ultrassônicas não influenciou na resistência à tração diametral dos CIV testados independentemente do seu tempo de aplicação.


Introduction: The glass ionomer cement is a dental material that has limitations of use due to its mechanical properties, such as low wear resistance, hardness, tensile and compressive diametral. Based on this, this study investigated the effect of ultrasonic excitation on the GIC in different application times, through the diametral tensile strength. Material and Method: The materials used were Ketac Molar EasyMix (KME) and Ketac Cem EasyMix (KCE). Were made 10 specimens for each condition studied: control group, and the groups that received application of ultrasound for 15s, 30s and 45s, for both materials. The ultrasonic excitation was applied during the initial setting reaction of GIC, soon after its insertion into the silicone matrix. The values of the diametral tensile strength were analyzed by Shapiro Wilk test and ANOVA (α = 0.05). Result: The application of ultrasonic excitation showed no statistically significant effect on diametral tensile strength of the materials tested, regardless of the time of application (p > 0.05). The KME resistance showed statistically greater than the KCE (p = 0.023). Conclusion: The use of ultrasound waves did not influence the diametral tensile strength of CIV tested regardless of their time of application.


Subject(s)
Tensile Strength , Ultrasonics , Analysis of Variance , Glass Ionomer Cements
5.
Rev. odontol. UNESP (Online) ; 41(4): 221-225, jul.-ago. 2012. tab
Article in English | LILACS, BBO | ID: lil-667021

ABSTRACT

Introdução: A aplicação de ondas ultrassônicas no cimento de ionômero de vidro acelera a velocidade da reação de presa inicial e melhora as propriedades mecânicas do material. Objetivo: Este estudo avaliou a resistência máxima à tração de cimentos de ionômero de vidro após excitação ultrassônica e tempos diferentes de armazenamento de água. Material e método: Doze corpos de prova de cada material (Fuji IX GP, Ketac Molar Easymix e Vitremer) foram preparados e seis receberam aplicação de ultrassom por 30 segundos durante a reação de presa inicial. Após armazenamento de 24 horas ou 30 dias, foram seccionados em espécimes na forma de palito e submetidos ao teste de microtração. Os valores médios de resistência à tração foram avaliados pela análise de variância e teste de Tamhane com correção de Welch. Resultado: O cimento Vitremer apresentou as maiores médias de resistência à tração. Foi observado que o tratamento com ultrassom aumentou a resistência do cimento Fuji IX GP com 24 horas de armazenamento e esta se manteve após 30 dias de armazenamento (p< 0,05). No grupo controle, Fuji IX GP com 30 dias armazenamento apresentou resistência à tração maior que o armazenamento de 24 horas (p < 0,05). Conclusão: O tratamento com ultrassom aumentou a resistência à tração do Fuji IX GP, no período inicial de sua maturação.


Introduction: The application of ultrasound waves with a conventional dental ultrasonic scaler on glass ionomer cements surface accelerated initial setting reaction and improved the mechanical properties. Objective: This study evaluated the ultimate tensile strength of glass ionomer cements after ultrasonic excitation and different water storage times. Material and method: Twelve specimens of each material (Fuji IX GP, Ketac Molar Easymix and Vitremer) were prepared, and six of each received a 30-second ultrasound application during initial setting of the cements. After storage of the 24 hours or 30 days, the specimens were sectioned into stick to microtensile testing and the mean ultimate tensile strength values were submitted to Welch?s ANOVA and Tamhane?s test. Result: The results showed that the Vitremer presented the highest mean tensile strength. The chemically set Fuji IX GP presented significantly higher mean tensile strength after 30 days than after 24 hours of storage (p < 0.05). At 24 hours, the ultrasonically set Fuji IX GP presented significantly higher mean tensile strength than their counterparts set under standard conditions (p < 0.05). Conclusion: Treatment with ultrasound increased the tensile strength of Fuji IX GP in the early period of maturation.


Subject(s)
Tensile Strength , Ultrasonics , Analysis of Variance , Dental Cements , Mechanical Tests , Glass Ionomer Cements
6.
Araraquara; s.n; 2012. 100 p. ilus, tab.
Thesis in Portuguese | LILACS, BBO | ID: biblio-866850

ABSTRACT

Este estudo teve como objetivo investigar a resistência máxima à tração de reparos de restaurações de CIV, após diferentes protocolos de tratamento de superfície e aplicação US. Foram confeccionados 15 corpos de prova para cada grupo experimental, os quais passaram por termociclagem (500 ciclos, de 5ºC e 55ºC ± 2ºC) e tratamento de superfície previamente a confecção do reparo, conforme segue: G1 ­ sem tratamento; G2 ­ tratamento de superfície com fresa diamantada; G3 ­ abrasão à ar; G4 ­ ácido fosfórico à 35%; G5 ­ ácido poliacrílico à 11,5%; G6 ­ fresa diamantada e ácido fosfórico à 35%; G7 - fresa diamantada e ácido poliacrílico à 11,5%; G8 - abrasão à ar e ácido fosfórico à 35%; G9 - abrasão à ar e ácido poliacrílico à 11,5%. O reparo foi confeccionado com CIV pigmentado com rodamina, para facilitar sua distinção. A excitação ultrassônica foi aplicada durante 0, 15 ou 30s para cada grupo. Após 24h de armazenamento, os corpos de prova foram seccionados em espécimes em forma de palito, com 0,9 mm2 de área de união e submetidos ao ensaio mecânico de microtração. As superfícies fraturadas foram avaliadas em lupa estereoscópica e classificadas em coesiva, adesiva ou mista. Foi considerada como variável dependente a resistência máxima a tração, e independentes o tratamento de superfície e a aplicação de US. As condições de homogeneidade de variâncias e de normalidade dos erros experimentais foram comprovadas, respectivamente pelos testes de Levene e de Shapiro-Wilk, complementada por comparações múltiplas pelo teste de Tukey. Adotou-se o nível de significância de 5% para a tomada de decisões. Os maiores valores de resistência de união dos reparos de cimentos de ionômero de vidro foram obtidos com o tratamento de fresa diamantada e ácido fosfórico. A aplicação do US (30 s) favoreceu a resistência de união de reparos de ionômero após a combinação de tratamento mecânico com ácido poliacrílico. Houve a predominância da fratura coesiva no cimento envelhecido, seguida na maioria das vezes pela fratura coesiva no reparo. Diante de uma odontologia conservadora e preservativa podemos concluir que a união dos reparos de restaurações com cimento de ionômero de vidro foi favorecida quando o preparo da superfície do material remanescente foi realizado com fresa diamantada e aplicação de ácido fosfórico a 35%


The study aimed to evaluate the effect of different surface treatment protocols and the ultrasonic excitation on the microtensile bond stregth of the glass ionomer restoration repaired. A total of 135 specimens was made using an increment technique and it was thermocycled (500 cycles between 5ºC and 55ºC ± 2ºC). The specimens were separated into 9 groups of 15, and each group then received a different surface treatment before the repair prepare: G1 control, without treatment; G2 diamond bur; G3 air abrasion; G4 35% fosforic acid; G5 11,5% poliacrilic acid; G6 diamond bur and 35% fosforic acid; G7 diamond bur and 11,5% poliacrilic acid; G8 air abrasion and 35% fosforic acid; G9 air abrasion and 11,5% poliacrilic acid. The repair was prepared with glass ionomer cement (Ketac Molar Easymix) colored with saturated rhodamine B (Fluka, Buchs, Switzerland) for its distinction. The samples were submitted to the ultrasonic excitation during 0, 15 and 30 seconds and, then stored in 37°C ±2°C water during 24 h. Rectangular bar specimens with a cross-sectional area of 0.9 mm² were prepared and then submitted to the microtensile test. The fracture surfaces were evaluated under stereomicroscope and classified as cohesive, adhesive or mixed. Microtensile strength values are shown in MPa. The dependent and independent variables were considered, respectively, ultimate tensile strength and the surface treatments and ultrasonic excitation. The effects of each surface treatment and ultrasonic excitation on the microtensile strength (MPa) were determined by ANOVA and Tukey tests. The highest values of bond strength of repair of glass ionomer cement were obtained with the treatment of diamond cutter and phosphoric acid. The application of the U.S. (30 s) enhanced the bond strength of repair of ionomer after the combination of mechanical treatment with polyacrylic acid. There was a predominance of cohesive failure in cement aging, followed by mostly cohesive failure in the repair. Faced with a conservative and preservative dentistry we can conclude that the union of the restorations with glass ionomer cement repair was favored when the surface preparation of the remaining material was performed with diamond cutter and application of phosphoric acid 35%


Subject(s)
Rhodamines , Ultrasonics , Analysis of Variance , Data Interpretation, Statistical , Glass Ionomer Cements , Tensile Strength
7.
Rev. odontol. UNESP (Online) ; 39(4): 207-211, jul.-ago. 2010. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-580979

ABSTRACT

O objetivo do presente estudo foi investigar o desgaste superficial após a realização da técnica de microabrasão com o auxílio de espátula plástica ou taça de borracha em baixa rotação. Dez molares permanentes (superfície vestibular) foram utilizados para a avaliação do desgaste superficial, sendo divididos nos grupos: GE (espátula) e GT (taça). Os grupos foram submetidos a dez aplicações de pasta abrasiva composta de ácido fosfórico a 35% mais pedra pomes, com duração de 20 segundos cada, sob pressão de 30 g, utilizando-se a técnica de acordo com cada grupo experimental. Os espécimes foram avaliados em lupa estereoscópica acoplada a um programa de computador. Pôde-se observar para os grupos GE e GT que o desgaste médio foi de 21,20 e 22,75%, respectivamente, não se apresentando diferença estatística entre eles. Pode-se concluir que houve desgaste superficial de todos os grupos experimentais, independentemente da utilização de espátula plástica ou taça de borracha.


The aim of this study was to investigate the enamel wear permanent teeth after plastic stick or low speed rubber cup microabrasion. Ten permanent molars were selected to evaluate enamel wear which were sectioned into mesial and distal halves. Each half of the molars was randomly assigned to one of two experimental groups (n = 10) according to the enamel microabrasion technique: plastic stick (GE) or rubber cup (GT). In both the groups, the enamel was submitted to 10 applications of an abrasive paste comprised of 35% phosphoric acid and pumice powder. The paste was applied for 20 seconds under a pressure of 30 g using the instrument defined for each group (plastic stick or rubber cup). The specimens were evaluated under a stereomicroscope connected to a computer. The enamel wear no was statistically different between GE and GT, which presented a mean wear of 304.74 µm (21.20%) and 338.35 µm (22.75%). In conclusion, superficial enamel wear was seen for both the groups, independent of the technique used for the accomplishment of the microabrasion.


Subject(s)
Analysis of Variance , Dentition, Permanent , Enamel Microabrasion , Dental Enamel , Tooth Wear , Molar
8.
Rev. odontol. UNESP (Online) ; 39(4): 207-211, jul.-ago. 2010. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-874543

ABSTRACT

O objetivo do presente estudo foi investigar o desgaste superficial após a realização da técnica de microabrasão com o auxílio de espátula plástica ou taça de borracha em baixa rotação. Dez molares permanentes (superfície vestibular) foram utilizados para a avaliação do desgaste superficial, sendo divididos nos grupos: GE (espátula) e GT (taça). Os grupos foram submetidos a dez aplicações de pasta abrasiva composta de ácido fosfórico a 35% mais pedra pomes, com duração de 20 segundos cada, sob pressão de 30 g, utilizando-se a técnica de acordo com cada grupo experimental. Os espécimes foram avaliados em lupa estereoscópica acoplada a um programa de computador. Pôde-se observar para os grupos GE e GT que o desgaste médio foi de 21,20 e 22,75%, respectivamente, não se apresentando diferença estatística entre eles. Pode-se concluir que houve desgaste superficial de todos os grupos experimentais, independentemente da utilização de espátula plástica ou taça de borracha.


The aim of this study was to investigate the enamel wear permanent teeth after plastic stick or low speed rubber cup microabrasion. Ten permanent molars were selected to evaluate enamel wear which were sectioned into mesial and distal halves. Each half of the molars was randomly assigned to one of two experimental groups (n = 10) according to the enamel microabrasion technique: plastic stick (GE) or rubber cup (GT). In both the groups, the enamel was submitted to 10 applications of an abrasive paste comprised of 35% phosphoric acid and pumice powder. The paste was applied for 20 seconds under a pressure of 30 g using the instrument defined for each group (plastic stick or rubber cup). The specimens were evaluated under a stereomicroscope connected to a computer. The enamel wear no was statistically different between GE and GT, which presented a mean wear of 304.74 µm (21.20%) and 338.35 µm (22.75%). In conclusion, superficial enamel wear was seen for both the groups, independent of the technique used for the accomplishment of the microabrasion.


Subject(s)
In Vitro Techniques , Analysis of Variance , Molar, Third , Dentition, Permanent , Tooth Wear , Dental Enamel , Enamel Microabrasion
9.
J. Health Sci. Inst ; 26(4): 450-453, out.-dez. 2008. graf
Article in Portuguese | LILACS, BBO | ID: biblio-873819

ABSTRACT

Introdução - Na literatura ainda há muita controvérsia sobre as manifestações sistêmicas e locais durante a erupção dentária. O objetivo deste trabalho foi avaliar a ocorrência dessas manifestações durante a erupção dentária. Material e Método - Os dados foram obtidos por meio de levantamento de daos contidos em fichas de 153 crianças de 0 a 2 anos de idade pertencentes a um programa de atendimento domiciliar a bebês moradores do Assentamento Bela Vista, na zona rural de Araraquara - SP. Resultados - Os resultados apontaram que 63% dos bebês não manifestaram sinais ou sintomas durante o período de erupção dentária. Dentre as crianças que apresentaram sinais ou sintomas, 21% das ocorrências foram representadas por diarréia , 21% por inquietação, 19% por febre, 17% por salivação aumentada e 22% dos demais apresentaram coceira na gengiva, coriza e sono agitado. Conclusão - Com isso este trabalho verificou que mesmo sendo considerada um evento fisiológico, a erupção dentária apresenta sinais e sintomas


Subject(s)
Humans , Male , Female , Infant , Alternating Symptoms , Tooth, Deciduous , Tooth Eruption , Home Nursing , Data Interpretation, Statistical , Medical Records , Signs and Symptoms
SELECTION OF CITATIONS
SEARCH DETAIL